Why does my breaker keep tripping?

Updated August 2026

← All home symptoms

A breaker that trips again and again is most often a circuit overload, too many amp-hungry devices sharing one 15- or 20-amp circuit, which trips after a delay once the sustained current passes the breaker's rating. Move a space heater, hair dryer, or microwave to a different circuit and the trips usually stop. If it trips with almost nothing running, or trips the instant you reset it, work down the list below: that pattern points at a fault, not a load.

Safety first: repeated tripping means the breaker is doing exactly the job it was made for. Never quiet it by dropping in a higher-amp breaker: the wire behind the wall is sized for 15 or 20 amps, and forcing more current through it is how fires start inside a wall. If a breaker trips the instant you flip it back on, or trips with almost nothing plugged in, stop resetting it and call a licensed electrician.

Causes, most likely first

What makes a furnace do this, most to least common (Updated August 2026)
Cause How likely The fix Typical cost
Circuit overload (too many devices) Most common Move high-draw appliances to other circuits so the load stays under the 15- or 20-amp rating. It trips a minute or two after the load comes on. Free
Short circuit or ground fault Common Trips instantly on reset. Unplug everything, then have an electrician trace the damaged wire, cord, or outlet behind it. $100–400
Failing or weak breaker Occasional Years of tripping wear the mechanism so it trips below its rating. A pro tests it and swaps the breaker. $150–300 installed
Arc fault (AFCI-protected circuit) Occasional On newer AFCI-protected circuits, the breaker trips on arcing from a nicked wire or a noisy motor. A pro finds the arc or replaces a nuisance breaker. $40–250
Loose or shared neutral Rare A loose neutral on a multi-wire circuit trips the breaker intermittently. An electrician retorques and separates the shared neutral. $150–350

Check these first

  1. Note what was running when it tripped. A space heater, microwave, and toaster sharing one kitchen circuit is a classic overload.
  2. Switch off or unplug everything on the dead circuit, reset the breaker, then add loads back one at a time to find the culprit.
  3. Feel the timing: a trip after a delay under load points to an overload, while an instant trip on reset points to a short or ground fault.
  4. Look and sniff for a scorched smell, a warm outlet, or a damaged cord on that circuit before you reset again.
  5. Check whether it is an AFCI or GFCI breaker (a test button on the breaker itself); those trip on faults a standard breaker ignores.

Prevent it next time

Spread heavy loads so no single 15- or 20-amp circuit carries a space heater plus another big draw, and test your breakers on the yearly schedule so a weak one shows itself before it strands you. Breakers are not forever: most run 30 to 40 years, and one that trips a little more each season is telling you it is near the end. The real cost of ignoring chronic trips is a charred bus bar or a fire, well past the $150–300 a swap runs.

When to call a pro

Call an electrician when the breaker trips instantly on reset, trips with the circuit nearly empty, or feels warm to the touch. Those point to a fault in the wiring, not your toaster. A diagnostic visit runs $100–200, tracing and repairing a short is $150–400, and a breaker swap is $150–300. If you find yourself resetting the same breaker daily, that is the moment to stop flipping it and get it looked at.

Most of the causes above are maintenance problems wearing a disguise. OnOtto keeps the boring prevention on schedule so the 2 a.m. version doesn't happen.

Stop chasing symptoms, free for 30 days

Frequently asked questions

Is it safe to keep resetting a breaker that trips?

Once or twice to find an overload, yes. But if it trips right back the moment you flip it on, stop. An instant re-trip means a real short or ground fault, and repeated arcing at the breaker can pit the contacts and heat the bus bar. Sort the difference by timing: an overload trips after a delay under load, while a breaker that trips right after reset is a fault to trace, not a switch to fight.

Can I put in a bigger breaker to stop the tripping?

No, and it is dangerous. The breaker is matched to the wire gauge: 15 amps for 14-gauge, 20 amps for 12-gauge. Swap a 15 for a 20 and the wire can overheat long before the breaker ever trips, which is a fire hazard inside the wall. The correct fix is to reduce the load on the circuit or add a new circuit, never to raise the breaker's amp rating past what the wire can carry.

Why does my breaker only trip when I run the microwave and toaster together?

That is a textbook overload. A 15-amp circuit carries about 1,800 watts and a 20-amp about 2,400. A microwave near 1,200 watts plus a toaster near 1,000 blows past 1,800, so the breaker cuts power to protect the wire. Move one appliance to a different circuit, or have an electrician add a dedicated 20-amp kitchen circuit for roughly $250–600. Running both on one small circuit will trip it every time.

What's the difference between a breaker tripping and a GFCI tripping?

A standard breaker trips on overload or short circuit to protect the wiring. A GFCI trips on a tiny current leak to ground, a matter of milliamps, to protect you from shock. If an outlet loses power but the panel breaker looks fine, you likely have a tripped GFCI upstream instead. They are separate protections, and the same circuit often carries both. Check the outlets for a popped GFCI reset button before you blame the panel.

Related reading