What is an R-value?

Updated August 2026

← The homeowner's glossary

R-value is the number that measures how well a material resists heat flow, where a higher R means heat moves through it more slowly. Materials are rated per inch and assemblies add up, so 10 inches of blown fiberglass at R-3.2 per inch gives you about R-32, and laying R-25 of new cellulose over existing R-13 batts gets you to R-38. The U.S. Department of Energy recommends roughly R-38 to R-60 in attics depending on climate zone. Most American attics built before 2000 sit well under that.

Where it is

You meet the number in four places: printed on the face of every batt, stamped on blown-insulation bags, written on the coverage card a contractor staples to a rafter after the job, and on window labels, where the industry uses U-factor, the inverse, instead. To find out what you already have, climb into the attic and push a tape measure straight down through the insulation in three or four spots, away from the hatch. Then convert with the rough per-inch values: fiberglass batt R-3.1–3.4, blown fiberglass R-2.2–2.7, blown cellulose R-3.2–3.8, rigid XPS foam board R-5, and closed-cell spray foam R-6–7. Eight inches of old blown fiberglass, a common finding, is about R-19.

What it does

R-value describes resistance to conducted heat and nothing else, which is where most insulation projects go wrong. It says nothing about air leakage, so a wall rated R-19 with gaps at the top plate performs closer to R-13; fiberglass filters air rather than stopping it. Air-sealing the attic plane first (top plates, wiring penetrations, the chimney chase, recessed cans, the hatch) costs $300–800 and returns more per dollar than the insulation above it. Compression is the second thief: an R-19 batt stuffed into a 3.5-inch cavity delivers about R-13, and plywood storage decking does the same to attic fill. Water is the third, because wet insulation loses most of its R until it dries, the real story behind a frosty or wet attic in winter. Too little R shows up as ice dams, a second floor the HVAC never satisfies, and ceiling joists poking above the insulation.

Maintenance

Insulation does not wear out, but it settles, gets shoved aside by anyone who crawls up there, and gets ruined by roof leaks, so look once a year using the attic insulation inspection guide. Blown cellulose settles 10–20 percent in its first few years, so a fresh R-38 job measures lower later. Topping up costs $1–2 per square foot installed, one of the highest-return projects in the house; skimping on attic insulation shows the shortfall per winter, and how long attic insulation lasts covers when material needs replacing. One note on incentives: the federal 25C energy-efficiency tax credit expired on December 31, 2025, so price the job on its merits and check your utility for a rebate.

What it costs to replace

A replacement R-value runs $1–2 per square foot of attic: adding R-30 of blown insulation over 1,200 square feet costs $1,200–2,400.

OnOtto's photo scan identifies parts like this in your home and builds the maintenance schedule for you. See how the scan works.

Frequently asked questions

How much attic insulation do I need in my climate?

DOE guidance runs R-30 to R-49 across the warm South, R-49 in the middle of the country, and R-49 to R-60 in the cold northern zones. Translated into depth, R-49 is roughly 14 inches of blown cellulose or 18 inches of blown fiberglass. If you can see the tops of your ceiling joists, you are at R-19 or less no matter where you live, and topping up is worth doing this year.

Can an attic have too much insulation?

Returns diminish rather than reverse. Going from R-19 to R-49 cuts attic heat loss substantially; going from R-60 to R-80 saves so little that the payback runs past 30 years. Two real limits matter more than the number: never block soffit vents, which starves attic ventilation, and never bury a recessed light that is not rated IC, which creates a fire hazard. Keep 3 inches of clearance or install airtight IC-rated covers.

Should I remove the old insulation before adding more?

Usually no. New blown insulation goes right over old batts and adds its full R-value, and removal costs $1–2 per square foot you do not need to spend. Remove it in three cases: it is wet or moldy from a roof leak, it is contaminated with rodent droppings, or it is vermiculite, the grey-brown pebbly material that may contain asbestos. Test vermiculite before disturbing it, and budget $2–8 per square foot for abatement.

Is R-value the same as U-factor?

They are inverses. R measures resistance to heat flow and higher is better; U measures the rate of heat transfer and lower is better. Windows use U-factor, so a U-0.30 window equals about R-3.3, which is why even a good window insulates like a sliver of wall. Worth remembering before spending $8,000–20,000 on replacement windows while the attic still measures R-19.